希而科*欧洲工控产品 物流快 * 希而科工业控制设备(上海)有限公司 :
公司历史:Silkroad24于1999成立,16年备件销售积累,励志成为国内“零出错率”欧洲工业自动化仪器仪表,备品备件供应商。 公司规模:100人左右 公司模式:德国本土采购,德国仓库拼单操作,为客户节约了成本,提高了采购效率。提供原装产品,真正做到了让客户服务满意,采购放心。 航班周期:每天安排航班,保证货物时效, 货物包装:长期以来积累了大量货物运输包装经验,所有货物均在国内进行二次包装,规避国内运输风险。 售后服务:客服,返修集中操作,完善的售后系统确保客户无后顾之忧。 处理效率:ERP系统做单,可以提供订单全程查询。 品牌 型号 When using power supplies in redundancy, decoupling diodes must be used to avoid one power supply to feed its power into the output of another power supply. Are power supplies from Kniel prepared for redundancy operation (1.3.3) DemoApp2 Our digitally programmable power supplies can be operated remoy from a PC by means of a LabVIEW application. Each of these power supplies comes with a data carrier loaded with this application. Where do I find firmware, drivers and other software like DemoApp or LabVIEW VIs for download (0.3.1) Description The description (where applicable) is part of the manual of a power supply and covers a broader view on the application of the power supply. Together with the datasheet the description makes the manual of the product. Both documents should be available to the qualified personnel that sets the power supply up. The datasheet of a power supply can be found on the productpage of the power supply and in the tables. Digital interfaces Our digitally programmable power supplies offer several interfaces, sometimes as option: RS232, USB, CAN, LAN. What is the difference between CAN-Bus and CANopen (1.5.3) Does the digital interface allow to control Kniel power supplies remoy (1.5.4) DIN EN ISO 9001 Certificate DIN-rail mounting A wide range of our power supplies are suitable for mounting on DIN-rails according to EN 50022 or can be adapted to be so. How does one find out, which wall bracket goes with which 19”-unit (3.2.2) Can I order power supplies ready for mounting on walls or DINrails ex works or do I have to retrofit the wall bracket and/or rail mounts How can I order this (3.2.3) Discontinued We can pronounce a type discontinued. Usually this means, the product will still be available for purchase for a given time. For new projects the customer should go for the successor type. How do I know which type is the successor of an outdated unit (0.4) Dodd-Frank Act You find our current declaration as PDF here http://kniel.de/download/Kniel-Kundeninformation- Dodd-Frank-Act.pdf in german and herehttp://kniel.de/download/Kniel-customer-information-Dodd- Frank-Act.pdf in english. Downloads Datasheet and description of each power supply can be found on the product page of the unit and in the column Manual in the tables. Depending on the article, more files are available, eg 3D- data or software. Driver The USB driver for our digitally programmable power supplies can be found on the accompanying data carrier. E EDS data The EDS data for our digitally programmable power supplies can be found on the accompanying data carrier. Electronic load Some of our power supplies have an integrated electronic load. energy... Part of the name od several series of power supplies for 19"-systems. Always connected with a number, indicating roughly the nominal output power. Eg energy 1200 installation, energy 3000. Extern ON/OFF Power supplies equipped with Extern ON/OFF can be switched off be applying an external voltage to an input (or on again if the voltage goes away). The exact function is explained in the description of the power supply. Is it mandatory to connect the Extern ON/OFF“-input (1.1.1) How does the Extern ON/OFF“-input work (1.1.2) F Firmware Our digitally programmable power supplies (energy..., energy ... installation) have their own internal software. This software is subject to constant developement. The latest release for each unit can be found on the pwodurct page of the unit. You need our Flashtool to replace the firmware. Flashtool Our Flashtool is the tool to update the firmware in your digitally programmable power supply (energy..., energy ... installation). Full rack width Some of our power supplies are designed to take the full width (84HP) of a 19“ rack, eg energy 1500, energy 3000. Power supply in full rack width Does Kniel build complete sub racks (0.2.2) G Guarantee See warranty. Guide rails Guide rails hold power supplies in a 19"-rack. Guide rails are directional dependant; the right rails must be mounted inverted. Is it normal, that the power supply needs quite some force to be pushed into the 19”-system (3.1.3) H HP HP is a dimension unit of the 19”-system and is used to indicate the height of a unit. One HP - front panel related - equals to 1.75” or 44.45mm. What does U and HP stand for (3.1.1) I Input voltage ranges Depending on the topolpgy our power supplies are equipped with different ranges for the input voltage. DC/DC-converters have input voltage ranges between 18 Vdc and 300 Vdc: 18 - 36 Vdc 36 - 75 Vdc 43 - 53 Vdc 75 - 150 Vdc 150 - 300 Vdc Units with AC input are either designed for 115 Vac or 230 Vac or can accept both input voltages. Depending on series the units have a wide range input, automatic range selection or can be switched manually between the ranges. Units of the series energy 3000 need a 3-phase mains input (3x400 Vac). installation Part of the name of a series of power supplies especially designed for mounting on walls like electrical cabinets. Eg energy 400 installation, energy 1200 installation. Matching variants of our Modules are available, too. Units of other serieses can be retrofitted or adapted. L LabView VI To make integration of our digitally programmable power supplies (energy..., energy ... installation) into your automated processes as easy as possible, we deliver not only the DemoApp with which you can control the power supply from a PC but als LabVIEW VIs ythat you can integrate into your own applications. DemoApp and LabVIEW VIs accompany the power supply on delivery. You can find the current version on the product page and in the details view in the tables. LabVIEW is a product from National Instruments. Lantronix For our power supplies with LAN interface we use an Ethernet module called XPort fromLantronix . Two installers from Lantronix are required to enable your PC to connect via the LAN interface to the power supply. Please make sure your computer has the current version of Microsoft .NET Framework 4 installed, as both Lantronix applications require it. The Device Installer is used to assign IP and other network specific addresses to the XPort module in your power supply. The Com Port Redirector maps the TCP/IP connection to the XPort in your power supply - configured with the device installer as stated above - onto a virtual COM port. Where do I find Lantronix Device Installer and COM Port Redirector Installer setup files (0.3.6) low emission A circuit technology developed by Kniel to combine the advantages of linear regulators and switched power supplies. M MD5 checksum To enable you to check the integrety of the file you downloaded from us, we use MD5 checksums. The checksums are shown near the download link. We only create checksums for files that get wrapped in an ZIP archive. We do not calculate checksums for PDF files. The checksum is always calculated from the file in the ZIP archive, never from the resulting archive. You have to unpack the ZIP file before you can check the checksum of the contained file. See also: https://en.wikipedia.org/wiki/MD5 . For Windows Microsoft offers a tool to verify MD5 checksums: https://support.microsoft.com/en-us/help/841290/availability-and-description-of-the-file- checksum-integrity-verifier-utility . Mechanic shapes Depending on electrical and mechanical application and technology our power supplies come in different mechanical shapes. See Block, Cassette, installation, Modul, Steckcompact, Steckkarte, Volleinschub. Module (german: Modul) A Kniel specific term for a mechanical shape of power supplies. Besides of ventilation openings a Module is compley enclosed. Depending on output power Modules come in different length while all have the same cross section. Modules are available for 19“ systems, for wall mounting and for DIN-rail mounting. Modules can come as switchers with AC or DC as input (lacquered RAL6026) Modules lacquered in RAL6026 and as low emission in transparent chromatized. low emission Modules in transparent chromatized N Nemko Norges Elektriske Materiellkontroll is a private norwegian organisation for testing and the certification of electrical equipment. Some of our products carry the N-logo. What does Nemko stand for (1.6.3) O Order number (german: Artikelnummer) Article numbers consist of 8 digits and follow the pattern 123-456-78. The dashes are significant. Over voltage protection (OVP) (german: überspannungsschutz üSS) Protects a power supply against voltages on the outputs that exceed a given limit. What is OVP (over voltage protection) german: üSS (überspannungsschutz) (1.5.5) P Part number (german: Artikelnummer) Power Boost Our power supplies deliver their rated power output up to 70°C ambient temperature. Up to 45°C ambient temperature many of our power supplies can deliver more, we call this Power Boost (PB). You find whether your power supply has this feature and the value of it if applicable in the datasheet of the power supply. PQube PQube is a modular system for monitoring the quality of a power grid and energy consumption. What is PQube (4.0) Pre fuse The data sheets of our power supplies contain information about the integrated fuse and the inrush current. How should a pre-fuse be dimensioned (1.6.1) Primary switcher (german: Primrschaltregler) Switched power supply with DC as input voltage, comes in different housing variants. Programming Many of our power supplies can be analog and/or digital programmed. Digital programming is done either directly on the unit, by using an external control unit (HMI) or from your PC via one of several interfaces (RS232, USB, CAN, LAN). In most cases analog programming is done using a programming voltage (typically 0-5V or 0-10V) or resitance (typically 0-10kΩ). Additionally all of our regulted power supplies are adjustable. Meaning, the output voltage can be altered in a given range around the nominal output voltage using the potetiometers at the front panel. The range depends on the unit in question. Q QPS QPS is a service recognized as NRTL (Nationally Recognized Testing Laboratory). Our qualified products carry the QPS certification mark. Quality management system (QS) R REACH Registration, Evaluation, Authorisation and Restriction of CHemicals REACH-Erklaerung.pdf in german and herehttp://kniel.de/download/Kniel-customer-information- REACH-declaration.pdf in english. Where do I find information concerning REACH (0.3.2) Recessed installation If multiple components should vanish behind a common front panel, the components must support recessed installation meaning they have a shortened front panel or none at all. Many of our power supplies are available in a housing variant suited for recessed installation. Repairs We offer to repair our products as a service. This service is subject to a charge if the repair is not covered by our 5 year guarantee. Who can help me if a Kniel product needs repair or calibration (0.5.1) RoHS 希而科优势销售欧洲*工业备件 希而科优势销售欧洲*工业备件
|